You are now viewing the owner's manual for your Broan Ventilation Hood, model number .This guide is designed to help you understand the features, functionalities, and maintenance requirements of your Ventilation Hood. Remember, your Broan Ventilation Hood is not just an appliance; it's an investment in your daily comfort and convenience. Please take a moment to familiarize yourself with this manual to ensure you get the most out of your Broan Ventilation Hood.

background image

!

FAN/LIGHT COMBINATION VENTILATORS / VENTILADORES CON LÁMPARA

MODELS / MODELOS 678 •  678MX • 679 • 679FLT • 680 • 680FLT

WARNING  

 

TO REDUCE THE RISK OF FIRE, ELECTRIC

SHOCK, OR INJURY TO PERSONS, OBSERVE

THE FOLLOWING:

1. Use this unit only in the manner intended by the

manufacturer. If you have questions, contact the manu-

facturer at the address or telephone number listed in

the warranty.

2. Before servicing or cleaning unit, switch power off at

service panel and lock the service disconnecting means

to prevent power from being switched on accidentally.

When the service disconnecting means cannot be

locked, securely fasten a prominent warning device,

such as a tag, to the service panel.

3. Installation work and electrical wiring must be done

by a qualified person(s) in accordance with all appli-

cable codes and standards, including fire-rated con-

struction codes and standards.

4. Sufficient air is needed for proper combustion and

exhausting of gases through the flue (chimney) of fuel

burning equipment to prevent backdrafting. Follow

the heating equipment manufacturer’s guideline and

safety standards such as those published by the

National Fire Protection Association (NFPA), and the

American Society for Heating, Refrigeration and Air

Conditioning Engineers (ASHRAE), and the local code

authorities.

5. When cutting or drilling into wall or ceiling, do not

damage electrical wiring and other hidden utilities.

6. Ducted fans must always be vented to the outdoors.

7. If this unit is to be installed over a tub or shower, it

must be marked as appropriate for the application and

be connected to a GFCI (Ground Fault Circuit Inter-

rupter) - protected branch circuit.

8. Never place a switch where it can be reached from a

tub or shower.

9. Fluorescent models only: Do not use a dimmer

switch to control the light of this unit.

10. This unit must be grounded.

CAUTION

1. For general ventilating use only. Do not use to

exhaust hazardous or explosive materials and

vapors.

2. This product is designed for ceiling installation

only. This product is designed for installation in

ceilings up to a 12/12 pitch. Ductwork must point

up. DO NOT MOUNT THIS PRODUCT IN A

WALL.

3. To avoid motor bearing damage and noisy and/

or unbalanced impellers, keep drywall spray,

construction dust, etc. off power unit.

4. Please read specification label on product for

further information and requirements.

Installer: Leave this manual with the

homeowner.

Homeowner: Use and Care information

on page 4.

READ AND SAVE THESE

INSTRUCTIONS

TYPICAL INSTALLATIONS

HOUSING

CEILING

JOIST

MOUNTING TABS

GRILLE

CEILING

MATERIAL

POWER CABLE

HOUSING

CEILING

JOIST

MOUNTING TABS

GRILLE

CEILING

MATERIAL

POWER CABLE

4" ROUND

DUCT

ADDITIONAL

FRAMING

HOUSING MOUNTED TO ADDITIONAL FRAMING

Discharge 90

0

 to joists.

HOUSING MOUNTED DIRECTLY TO JOIST

2x6 (or larger)  Discharge parallel to joists.

HOUSING

2 x 4

CEILING

JOIST or

TRUSS

MOUNTING

TABS

CEILING

MATERIAL

POWER CABLE

ADDITIONAL

FRAMING

2 x 4

CEILING

JOIST or

TRUSS

GRILLE

HOUSING MOUNTED TO 2x4 TRUSS

Requires additional framing for mounting tabs.

Discharge parallel to joists.

HOUSING

MOUNTING

TABS

CEILING

MATERIAL

POWER CABLE

ADDITIONAL

FRAMING

"

I"

JOIST

"

I"

JOIST

GRILLE

HOUSING MOUNTED TO “I” JOIST

Requires additional framing for mounting tabs.

Discharge parallel to joists.

HOUSING

2 x 4

CEILING

JOIST or

TRUSS

MOUNTING TABS

CEILING

MATERIAL

POWER CABLE

4" ROUND

DUCT

ADDITIONAL

FRAMING

2 x 4

CEILING

JOIST or

TRUSS

GRILLE

HOUSING MOUNTED TO 2x4 TRUSS

Requires additional framing for mounting tabs.

Discharge 90

0

 to joists.

HOUSING

MOUNTING TABS

CEILING

MATERIAL

POWER CABLE

4" ROUND

DUCT

ADDITIONAL

FRAMING

"

I"

JOIST

"

I"

JOIST

GRILLE

HOUSING MOUNTED TO “I” JOIST

Requires additional framing for mounting tabs.

Discharge 90

0

 to joists.

*

Additional framing must be a 2x6 (minimum height), at
least 9-inches long.

*

*

*

*

ADVERTENCIA

PARA REDUCIR EL RIESGO DE INCENDIO, DESCAR-

GA ELÉCTRICA O LESIONES PERSONALES, OBSER-

VE LO SIGUIENTE:

1. Utilice esta unidad solamente de acuerdo con las

instrucciones del fabricante. Si tiene preguntas

comuníquese con el fabricante a la dirección o al número

telefónico que se indica en la garantía.

2. Antes de dar servicio o limpiar la unidad, interrumpa el

suministro de energía en el panel de servicio y bloquee los

dispositivos de desconexión para evitar la reinstalación ac-

cidental de la energía. Cuando no se puedan bloquear los

dispositivos de desconexión, fije seguramente en el panel

de servicio un medio de advertencia que sea visible, como

por ejemplo una etiqueta.

3. Una persona o personas calificadas deben realizar el

trabajo de instalación y el cableado eléctrico, de acuerdo

con todos los códigos y normas aplicables, inclusive los

códigos y normas de construcción para evitar incendios.

4. Se necesita suficiente aire para que se realice la combustión

y la descarga de gases adecuadas a través de la chimenea

del equipo para quemar combustible a fin de evitar las

corrientes de inversión. Observe los lineamientos del

fabricante del equipo de calefacción y las normas de

seguridad, como por ejemplo las publicadas por la Asociación

Nacional de Protección contra Incendios (National Fire Pro-

tection Association: NFPA), y la Sociedad Americana de

Ingenieros en Calefacción, Refrigeración y Sistemas de

Acondicionamiento de Aire (American Society for Heating,

Refrigeration and Air Conditioning Engineers: ASHRAE), y

los códigos locales.ditioning Engineers (ASHRAE), and the

local code authorities.

5. Cuando corte o perfore la pared o el cielo raso, tenga

cuidado de no dañar el cableado eléctrico ni otras

conexiones de servicios que se encuentren ocultas.

6. Los ventiladores con conductos siempre deben tener salida

hacia el exterior.

7. Si se va a instalar esta unidad sobre una tina o ducha, debe

marcarse que es apropiada para esta aplicación y

conectarse a un GFCI (interruptor accionado por pérdida

de conexión a tierra) en un circuito de derivación protegido.

8. Nunca coloque el interruptor en un lugar en donde se pueda

alcanzar desde la tina o ducha.

9. Modelos fluorescentes solamente: No emplee un

interrupto reductor para controlar la luz de esta unidad.

10. Esta unidad debe conectarse a tierra.

PRECAUCIÓN

1. Esta unidad debe usarse solamente para ventilación gen-

eral. No la utilice para la descarga de materiales ni vapores

peligrosos o explosivos.

2. Este producto está diseñado solamente para instalarse en

el cielo raso. Este producto está diseñado para instalarse

en cielos rasos con una pendiente de hasta 12/12. El sistema

de conductos debe apuntar hacia arriba. NO MONTE

ESTE PRODUCTO EN LA PARED.

3. Para evitar causar daño a los cojinetes del motor y pistones

impulsores ruidosos y/o no balanceados, mantenga los

aerosoles para pirca, el polvo de construcción, etc. lejos del

motor.

4. Por favor consulte la información y los requerimientos

adicionales contenidos en la etiqueta de especificaciones

que se encuentra en el producto.

A la persona que realiza la instalación:

Deje este manual con el dueño de la

casa.

Al dueño de la casa: Las instrucciones

de operación y limpieza se encuentran

en la página 4.

!

LEA Y CONSERVE ESTAS

INSTRUCCIONES

*