You are now viewing the owner's manual for your Creda Air Conditioner, model number .This guide is designed to help you understand the features, functionalities, and maintenance requirements of your Air Conditioner. Remember, your Creda Air Conditioner is not just an appliance; it's an investment in your daily comfort and convenience. Please take a moment to familiarize yourself with this manual to ensure you get the most out of your Creda Air Conditioner.

background image

Wattage (W) 

Model  with 

controls white 

Model with controls 

silver 

Model  with no 

controls white 

Dimensions 

(mm) 

500 

NPP50 75-773001 

NPP50S 75-773011 

NP50 75-772901 

442 x 430 x 80 

1000 

NPP100 75-773002 

NPP100S 75-773012 

NP100 75-772902 

680 x 430 x 80 

1500 

NPP150 75-773003 

NPP150S 75-773013 

NP150 75-772903 

680 x 430 x 80 

2000 

NPP200 75-773004 

NPP200S 75-773014 

NP200 75-772904 

852 x 430 x 80 

Creda Newera Profile and Profile Plus Panel Heaters 

Installation and Operating Instructions 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

The Newera Profile panel heater range is designed for wall mounting on the wall brackets supplied.  It 
should only be operated when in the upright position as shown in diagram C. 
All models are protected against moisture ingress to IPX4 standard. 
All models, except those with no controls, are fitted with a 7-day digital programmer. 
Installation: 
Before connecting the heater, check that the supply voltage is the same as that stated on the rating label. 
When selecting the position for the heater to be installed, consideration should be given to ensure that there 
are no obstructions closer than the dimensions given in Diagram C.  The bracket for the heater should be 
fitted in accordance with the method detailed in the associated diagrams.  The heater must not be located 
below a socket outlet or connection box. 
Care must be exercised when fitting the heater onto the bracket.  Pressure should only be applied to 
the ends of the heater and not to the grille area. 
The electrical installation must be carried out by a competent electrician and in accordance with the current 
Electrical Wiring Regulations (BS7671) and/or local regulations. 
The heater is fitted with a length of flexible cable for connection to the fixed wiring of the premises via a 
suitable connection box positioned adjacent to the heater. 
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly 
qualified persons in order to avoid a hazard. 
A means for disconnection in all poles must be incorporated in the fixed wiring in accordance with 
the wiring rules. 

WARNING – THIS APPLIANCE MUST BE EARTHED 
WARNING – In order to avoid overheating, do not cover the heater.