You are now viewing the owner's manual for your Henny Penny Electric Food Steamer, model number .This guide is designed to help you understand the features, functionalities, and maintenance requirements of your Electric Food Steamer. Remember, your Henny Penny Electric Food Steamer is not just an appliance; it's an investment in your daily comfort and convenience. Please take a moment to familiarize yourself with this manual to ensure you get the most out of your Henny Penny Electric Food Steamer.

background image

CSL
CSM
CSB

62

INTRODUCTION

This section provides the installation instructions for the Henny Penny Electric Combi-Steamers.

NOTE: The installation of this unit must conform to all local, state, and federal codes.  In the absence of codes use
ANSI/NFPA No. 70-latest edition.

NOTE: Canadian installations must conform with the Canadian electrical code, C22.1, Part 1 and/or local codes.

NOTE: The installation of this equipment should be performed by a qualified technician.

LOCATION

The proper location of the unit is very important for operation and convenience.  Choose a location which will provide easy
loading and unloading without interfering with the final assembly of food orders.

NOTE: Adequate clearance must be provided for servicing and for operation.

Table Units:

Minimum clearances have to be maintained from the adjacent walls.

Left Side  

Right Side  

Back Side

CSB,CSM,CSL-6, 10, 1020 

6” (150mm)

2” (50mm)

2” (50mm)

NOTE: 14” (350mm) is recommended at the left side of the unit for service purposes.

Place the combi-steamer on an original Henny Penny stand or on a level and sturdy surface.  Recommended stand height
is 28.5” (725mm).

Minor unevenness of the surface/floor can be compensated by adjusting the legs of the stand or the appliance.

The weight of the units are as follows:

CSB, CSM, CSL-6

297 lbs.

(134.5 kg)

CSB, CSM, CSL-10

349 lbs.

(158.0 kg)

CSB, CSM, CSL-1020

507lbs.

(230.0 kg)

Installation planning should encourage sufficient space to keep the transport trolley/mobile rack at the left-hand side
of the unit.

NOTE: Ventilation must conform to local, state and national codes. Consult your local fire department or building authorities.

X

Do Not puncture the cabinet with any objects such as drills or screws as electrical shock, or component
damage could result.

X

When moving the unit with a pallet jack ensure it is located under the 1-5/8” x 1-5/8” structure frame before
lifting the unit.

Installation – Electric Units